Catalog /RunTru by Trane

RunTru by Trane
RunTru A5HP4 Heat Pump Condenser — 14.3 SEER2, R-454B
Heating and cooling in one efficient, value-built unit.
Pay over time with Shop Pay — your options and terms are shown at checkout. How payment works
Our promise on every order
- Typically ships in 3–7 business days — crated and moved by LTL freight from Southwest Florida. The carrier then schedules delivery with you.
- Manufacturer specifications, published — model number, capacity, efficiency and refrigerant are all listed below, so you can check this against what your contractor specified.
- Check your match in seconds — put in the two model numbers you were quoted and see whether that pair is AHRI-certified before you spend anything. Not sure, or not our equipment? Send them to us and we will look them up by hand.
- 30 days to return unopened equipment — full returns policy.
What's included, and what your installer supplies Ships as one crate by freight. Installation is not included.
In the box: the outdoor condenser only. It comes with its factory refrigerant charge. It needs a matched indoor unit: check the AHRI match, or read replacing just the condenser.
Your installer supplies the line set (or reuses yours if it qualifies: reuse or replace?), electrical disconnect and whip, thermostat and control wire, condensate drain and float switch, a condenser pad or wall brackets, and the permit.
Installation is by your licensed HVAC contractor. How to find one.
About this unit
One box that heats and cools
A heat pump is an air conditioner that can run in reverse. In summer it moves heat out of the house; in winter it reverses and moves heat in. Across Florida and the lower South that covers effectively the whole heating season, with the air handler's electric heat strips carrying the handful of nights it cannot. There is no gas line, no flue and no combustion anywhere in the system — which is why heat pumps dominate new installations in this part of the country.
Trane's value brand, in a heat pump
RunTru is Trane Technologies' economy tier: the same company behind Trane, engineered to a simpler specification and priced for builders. On a heat pump that matters more than it does on a straight air conditioner, because a heat pump runs year round rather than seasonally. You want the reversing valve and compressor to come from a manufacturer whose parts are stocked locally in eight years' time, and you want a technician to be able to work on it without a factory-only tool.
14.3 SEER2 at the compliant floor
14.3 SEER2 is the minimum the current federal standard allows on a new split system across the southern states. For a rental, a flip, or any property where the occupant pays the utility bill, that is the rational place to buy: a current-generation unit at the lowest compliant efficiency, with nothing spent on savings you will not personally collect.
R-454B, the refrigerant going forward
This unit ships on R-454B rather than R-410A. R-410A equipment still being sold is previous-generation stock on a refrigerant in scheduled phase-down, which gets more expensive to service every year. A heat pump runs far more hours annually than an air conditioner does, so the refrigerant it uses matters more over its life.
Matching it correctly, and the part people forget
The A5HP4 pairs with the RunTru A5AHC multi-position air handler, and your SEER2 and HSPF2 ratings belong to that certified pair rather than to the condenser alone — the AHRI reference number is published on the listing. One thing buyers routinely miss: a heat pump needs an electric heat kit in the air handler for supplemental heat, and it is sized to your climate and sold separately. It is listed in our accessories, and your installer should specify the kW rating.
HVAC Supply Pro LLC is an independent retailer. We are not affiliated with, endorsed by, or an authorized dealer of Trane, RunTru or Everwell; brand names are used only to identify the equipment we sell. All equipment is new, in its original factory packaging.
Product photos are representative manufacturer images; actual appearance may vary slightly.
Key features
- 14.3 SEER2 cooling + efficient electric heating
- R-454B low-GWP refrigerant
- Single-stage, all-in-one heating & cooling
- All-aluminum coils, weather-resistant cabinet
- Trane-built reliability — pairs with the A5AHC air handler
RunTru is Trane's value line. Designed, built and tested by Trane, sold without the Trane price.
- Same manufacturer, same engineering discipline. RunTru is not a rebadged import — it is Trane's own product, built to Trane's standards. The badge is different; the build is not.
- Single-stage and straightforward. Fewer parts to fail, and any technician in the country can service it without specialist training or proprietary tools. On a rental you do not want to be waiting on a specialist in August.
- All-aluminum coils. These resist the galvanic corrosion that eats copper-and-aluminum coils in coastal and high-humidity air — a real advantage in exactly the climates this equipment sells into.
- Published warranty terms. Built by Trane Technologies. RunTru publishes its own warranty terms, similar in structure to Trane's. Check them at runtruhvac.com/warranty.
- Built for the jobs it sells into. Rentals, flips, builder work and straight like-for-like replacements — where what matters is that it runs, that it is cheap to service, and that it did not cost premium money.
Specifications & documents
Manufacturer-published figures for the model you have selected above.
At a glance
| Model number | A5HP4018A1000A |
|---|---|
| Capacity | 18,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 75 dB(A) |
Full specifications A5HP4018A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 2980 CFM |
| Max current | 20 A max breaker · 12 A min circuit ampacity |
| Net weight | 174.0 lb |
| Crate dimensions | 38.3 x 31.1 x 31.1 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 3/4 in gas × 5/16 in liquid Refrigerant 4 lb 12 oz R-454B, factory supplied Subcooling 9°F Outdoor coil All aluminum Crated (H×W×D) 38.3 × 31.1 × 31.1 in Shipping weight 208 lb
Manufacturer-published figures for A5HP4018A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4024A1000A |
|---|---|
| Capacity | 24,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 75 dB(A) |
Full specifications A5HP4024A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 2980 CFM |
| Max current | 20 A max breaker · 13 A min circuit ampacity |
| Net weight | 174.0 lb |
| Crate dimensions | 38.3 x 31.1 x 31.1 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 3/4 in gas × 5/16 in liquid Refrigerant 4 lb 10 oz R-454B, factory supplied Subcooling 12°F Outdoor coil All aluminum Crated (H×W×D) 38.3 × 31.1 × 31.1 in Shipping weight 208 lb
Manufacturer-published figures for A5HP4024A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4030A1000A |
|---|---|
| Capacity | 30,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 75 dB(A) |
Full specifications A5HP4030A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 2980 CFM |
| Max current | 25 A max breaker · 16 A min circuit ampacity |
| Net weight | 174.0 lb |
| Crate dimensions | 38.3 x 31.1 x 31.1 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 3/4 in gas × 5/16 in liquid Refrigerant 4 lb 10 oz R-454B, factory supplied Subcooling 12°F Outdoor coil All aluminum Crated (H×W×D) 38.3 × 31.1 × 31.1 in Shipping weight 208 lb
Manufacturer-published figures for A5HP4030A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4036A1000A |
|---|---|
| Capacity | 36,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 70 dB(A) |
Full specifications A5HP4036A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 4230 CFM |
| Max current | 30 A max breaker · 19 A min circuit ampacity |
| Net weight | 222.0 lb |
| Crate dimensions | 38.1 x 35.6 x 35.6 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 3/4 in gas × 5/16 in liquid Refrigerant 5 lb 10 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 38.1 × 35.6 × 35.6 in Shipping weight 256 lb
Manufacturer-published figures for A5HP4036A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4042A1000A |
|---|---|
| Capacity | 42,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 72 dB(A) |
Full specifications A5HP4042A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 4992 CFM |
| Max current | 40 A max breaker · 24 A min circuit ampacity |
| Net weight | 250.0 lb |
| Crate dimensions | 50.1 x 35.6 x 35.6 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 7/8 in gas × 5/16 in liquid Refrigerant 7 lb 14 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 50.1 × 35.6 × 35.6 in Shipping weight 300 lb
Manufacturer-published figures for A5HP4042A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4048A1000A |
|---|---|
| Capacity | 48,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 72 dB(A) |
Full specifications A5HP4048A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 4992 CFM |
| Max current | 40 A max breaker · 25 A min circuit ampacity |
| Net weight | 250.0 lb |
| Crate dimensions | 50.1 x 35.6 x 35.6 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 7/8 in gas × 5/16 in liquid Refrigerant 8 lb 9 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 50.1 × 35.6 × 35.6 in Shipping weight 300 lb
Manufacturer-published figures for A5HP4048A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5HP4060A1000A |
|---|---|
| Capacity | 60,000 BTU cooling |
| Efficiency | 14.3 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 72 dB(A) |
Full specifications A5HP4060A1000A
| System type | Heat Pump Condenser |
|---|---|
| Airflow | 4992 CFM |
| Max current | 50 A max breaker · 33 A min circuit ampacity |
| Net weight | 250.0 lb |
| Crate dimensions | 50.1 x 35.6 x 35.6 in |
| Warranty | Manufacturer's limited warranty from RunTru (a Trane brand), not HVAC Supply Pro. RunTru decides coverage. Its published terms require installation by a licensed HVAC professional and offer longer parts coverage if registered within 60 days. Review RunTru's terms, including exclusions, before you buy: runtruhvac.com/warranty. Labor is not covered. |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Refrigerant ctrl Expansion valve Line set 7/8 in gas × 5/16 in liquid Refrigerant 8 lb 6 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 50.1 × 35.6 × 35.6 in Shipping weight 300 lb
Manufacturer-published figures for A5HP4060A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5HP4 Split System Heat Pump — Product and Submittal Data (ODR-PSD034A-EN, June 2025)
- RunTru A5HP4 Heat Pumps — Installation, Operation and Maintenance (ODR-SVX010B-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
All models in this series
Every size we carry, with the full model number your installer and AHRI will ask for.
| Model number | Size | Price |
|---|---|---|
| A5HP4018A1000A | 1.5 Ton | $2,325.89 |
| A5HP4024A1000A | 2 Ton | $2,446.43 |
| A5HP4030A1000A | 2.5 Ton | $2,575.89 |
| A5HP4036A1000A | 3 Ton | $2,705.36 |
| A5HP4042A1000A | 3.5 Ton | $3,312.50 |
| A5HP4048A1000A | 4 Ton | $3,479.91 |
| A5HP4060A1000A | 5 Ton | $3,602.68 |
Reviews
Left by people who bought this from us.
Worth reading first
Written by HVAC Supply Pro.
- SEER2 Savings CalculatorPut your own system size, current rating and power bill in, and see what the efficiency step is worth per year.
- Why an AHRI-Matched System MattersWhy the condenser and air handler have to be a certified pair - and what goes wrong when they are not.
- R-454B vs R-410AThe refrigerant changeover, in plain terms - and why it matters on a system you keep 15 years.
Shipping & returns
- $349 delivered to your door, liftgate included — $499 to AZ, CA, CO, ID, MT, NM, NV, OR, UT, WA and WY. One flat price whatever it weighs, with nothing added at checkout. Ships to the 48 contiguous states and DC.
- Must be installed by a licensed HVAC professional — opening refrigerant lines requires EPA certification.
- 30-day returns on unopened equipment, 20% restocking fee. No returns on installed units.
How buying the equipment yourself works — the whole process, start to finish
You are buying the equipment from us and the labour from an installer you choose. Two numbers instead of one bundled quote — which is the point, but it does mean you are the one connecting them. Here is the whole sequence.
- Order the equipment. The price on this page is what you pay us. Nothing about installation is included in it, and nothing is added later.
- Line up your installer before it ships. This is the step people skip, and it is the one that causes trouble — equipment sitting in a garage while you ring round for someone free. You need a licensed HVAC professional; opening a refrigerant circuit requires EPA certification. Ask specifically what they charge to install customer-supplied equipment. How to find one.
- It ships crated on a freight truck. Orders typically ship within 3–7 business days. A complete system travels as two crates — condenser and air handler — which can arrive on different days. Delivery is to your address on a liftgate truck for one flat price, with nothing to choose at checkout. What delivery costs.
- The carrier calls to book a delivery window. That appointment is when your equipment arrives — not the ship date. Answer the call; an unanswered one is the most common cause of a delay.
- Inspect it before you sign. Two minutes at the tail of the truck decide whether a damage claim works. Note any damage on the delivery receipt specifically, not just "damaged", and photograph it before it comes off the truck. What to check.
- Your installer fits it. Line set, disconnect, whip, thermostat and equipment pad are not included — your installer supplies those. If the manufacturer's terms allow, register the equipment. Trane and RunTru offer longer parts coverage when registered within 60 days, subject to their conditions. Check the manufacturer's terms before you buy. Warranty terms.
Stuck on any of it, or not sure a pairing is right? Call (239) 266-9766 — you'll get a straight answer.