Catalog /RunTru by Trane

RunTru by Trane
RunTru A5AC5 Air Conditioner Condenser — 1.5 to 5 Ton, 15.2 SEER2, R-454B
A step up in efficiency, same Trane-built backbone.
Pay over time with Shop Pay — your options and terms are shown at checkout. How payment works
Our promise on every order
- Typically ships in 3–7 business days — crated and moved by LTL freight from Fort Myers, FL. The carrier then schedules delivery with you.
- Manufacturer specifications, published — model number, capacity, efficiency and refrigerant are all listed below, so you can check this against what your contractor specified.
- Check your match in seconds — put in the two model numbers you were quoted and see whether that pair is AHRI-certified before you spend anything. Not sure, or not our equipment? Send them to us and we will look them up by hand.
- 30 days to return unopened equipment — full returns policy.
About this unit
The same platform, with the efficiency step
The A5AC5 is the A5AC4's Trane-built platform with more coil surface and a higher-efficiency compressor. Certified between 15 and 16 SEER2 depending on tonnage when it is matched with the A5AHC air handler — the exact figure belongs to your specific pairing, and the AHRI reference number is published on every listing here so you can read it rather than take our word for it.
Who should pay for the step up
If you live in the house and pay the cooling bill, this is the one to buy. Through a Florida or Texas cooling season, moving from 14.3 to roughly 15.5 SEER2 is a measurable reduction on the largest electrical load in the building, recovered over a service life counted in a decade or more. If the property is a rental and the tenant pays the power, the A5AC4 is the more rational purchase and we would rather tell you that than sell you the more expensive box.
Rebates change the arithmetic
Matches at this efficiency level can reach ENERGY STAR qualification, which is the threshold most utility rebate programs use. Check it before you buy: a rebate on the efficient unit can close much of the price gap with the minimum-efficiency one, which changes which unit is actually cheaper. Programs are administered by your utility and change annually — our rebate guide explains where to look them up.
More efficiency, not more complexity
R-454B refrigerant, a single-stage compressor, all-aluminum coils, no inverter electronics. The efficiency here comes from the physical size of the heat exchanger and the quality of the compressor rather than from variable-speed control, which means there is no additional circuit board to fail in year nine. That matters for a system you intend to keep and have serviced by whoever is available on a July afternoon.
Matching it correctly
Pairs with the RunTru A5AHC. Because the rating belongs to the certified pair, buy the combination that appears on the AHRI certificate — a mismatched indoor coil is the most common reason a new system underperforms its label. The complete system is also listed as one item if you would rather not match it yourself.
Key features
- Up to 15.2 SEER2 efficiency
- R-454B low-GWP refrigerant
- Single-stage compressor — simple and reliable
- All-aluminum coils, insulated factory-sealed cabinet
- ENERGY STAR-eligible matches may qualify for utility rebates
- Pairs with the RunTru A5AHC air handler
RunTru is Trane's value line. Designed, built and tested by Trane, sold without the Trane price.
- Same manufacturer, same engineering discipline. RunTru is not a rebadged import — it is Trane's own product, built to Trane's standards. The badge is different; the build is not.
- Single-stage and straightforward. Fewer parts to fail, and any technician in the country can service it without specialist training or proprietary tools. On a rental you do not want to be waiting on a specialist in August.
- All-aluminum coils. These resist the galvanic corrosion that eats copper-and-aluminum coils in coastal and high-humidity air — a real advantage in exactly the climates this equipment sells into.
- The same warranty structure as Trane. Five years base on parts, ten with registration inside 60 days. The value line does not mean a value warranty.
- Built for the jobs it sells into. Rentals, flips, builder work and straight like-for-like replacements — where what matters is that it runs, that it is cheap to service, and that it did not cost premium money.
Specifications & documents
Manufacturer-published figures for the model you have selected above.
At a glance
| Model number | A5AC5018A1000A |
|---|---|
| Capacity | 18,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 73 dB(A) |
Full specifications A5AC5018A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 3000 CFM |
| Max current | 20 A max breaker · 9 A min circuit ampacity |
| Net weight | 184.0 lb |
| Crate dimensions | 42 x 31.1 x 31.1 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 3/4 in gas × 5/16 in liquid Refrigerant 3 lb 12 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 42 × 31.1 × 31.1 in Shipping weight 220 lb
Manufacturer-published figures for A5AC5018A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5024A1000A |
|---|---|
| Capacity | 24,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 71 dB(A) |
Full specifications A5AC5024A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 3070 CFM |
| Max current | 25 A max breaker · 14 A min circuit ampacity |
| Net weight | 161.0 lb |
| Crate dimensions | 38.3 x 31.1 x 31.1 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 3/4 in gas × 5/16 in liquid Refrigerant 3 lb 10 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 38.3 × 31.1 × 31.1 in Shipping weight 183 lb
Manufacturer-published figures for A5AC5024A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5030A1000A |
|---|---|
| Capacity | 30,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 73 dB(A) |
Full specifications A5AC5030A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 3000 CFM |
| Max current | 25 A max breaker · 15/17 A min circuit ampacity |
| Net weight | 184.0 lb |
| Crate dimensions | 42 x 31.1 x 31.1 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 3/4 in gas × 5/16 in liquid Refrigerant 3 lb 8 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 42 × 31.1 × 31.1 in Shipping weight 220 lb
Manufacturer-published figures for A5AC5030A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5036A1000A |
|---|---|
| Capacity | 36,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 71 dB(A) |
Full specifications A5AC5036A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 3130 CFM |
| Max current | 30 A max breaker · 18 A min circuit ampacity |
| Net weight | 161.0 lb |
| Crate dimensions | 38.3 x 31.1 x 31.1 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 3/4 in gas × 5/16 in liquid Refrigerant 3 lb 8 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 38.3 × 31.1 × 31.1 in Shipping weight 183 lb
Manufacturer-published figures for A5AC5036A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5042A1000A |
|---|---|
| Capacity | 42,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 71 dB(A) |
Full specifications A5AC5042A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 4850 CFM |
| Max current | 30 A max breaker · 21 A min circuit ampacity |
| Net weight | 212.0 lb |
| Crate dimensions | 42 x 35.6 x 35.6 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 7/8 in gas × 5/16 in liquid Refrigerant 5 lb 1 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 42 × 35.6 × 35.6 in Shipping weight 246 lb
Manufacturer-published figures for A5AC5042A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5048A1000A |
|---|---|
| Capacity | 48,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 71 dB(A) |
Full specifications A5AC5048A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 5170 CFM |
| Max current | 35/45 A max breaker · 23/25 A min circuit ampacity |
| Net weight | 257.0 lb |
| Crate dimensions | 50 x 35.6 x 35.6 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 7/8 in gas × 5/16 in liquid Refrigerant 6 lb 10 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 50 × 35.6 × 35.6 in Shipping weight 307 lb
Manufacturer-published figures for A5AC5048A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
At a glance
| Model number | A5AC5060A1000A |
|---|---|
| Capacity | 60,000 BTU cooling |
| Efficiency | 15.2 SEER2 |
| Power supply | 208-230V / 1Ph / 60Hz |
| Sound level | 71 dB(A) |
Full specifications A5AC5060A1000A
| System type | Central Air Conditioner Condenser |
|---|---|
| Airflow | 5260 CFM |
| Max current | 50 A max breaker · 28/30 A min circuit ampacity |
| Net weight | 252.0 lb |
| Crate dimensions | 50 x 35.6 x 35.6 in |
Dimensions & weight
Power supply 208/230V · 1 Ph · 60 Hz Compressor Scroll, single-stage Line set 1 in gas × 5/16 in liquid Refrigerant 5 lb 15 oz R-454B, factory supplied Subcooling 10°F Outdoor coil All aluminum Crated (H×W×D) 50 × 35.6 × 35.6 in Shipping weight 302 lb
Manufacturer-published figures for A5AC5060A1000A. Capacity and voltage differ between models in this series — confirm against the technical sheet before ordering.
Documents 2 items
- RunTru A5AC5 Split System Air Conditioner — Product and Submittal Data (ODR-PSD033B-EN, September 2025)
- RunTru A5AC5 Condensing Units — Installation, Operation and Maintenance (ODR-SVX034A-EN, April 2026)
Published by the manufacturer. Verify all details against the documentation shipped with your unit before installation.
Worth reading first
Written by people who install this equipment.
- SEER2 Savings CalculatorPut your own system size, current rating and power bill in, and see what the efficiency step is worth per year.
- Why an AHRI-Matched System MattersWhy the condenser and air handler have to be a certified pair - and what goes wrong when they are not.
- R-454B vs R-410AThe refrigerant changeover, in plain terms - and why it matters on a system you keep 15 years.
Shipping & returns
- $349 delivered to your door, liftgate included — $499 to AZ, CA, CO, ID, MT, NM, NV, OR, UT, WA and WY. One flat price whatever it weighs, with nothing added at checkout.
- Must be installed by a licensed HVAC professional — opening refrigerant lines requires EPA certification.
- 30-day returns on unopened equipment, 20% restocking fee. No returns on installed units.
How buying direct works — the whole process, start to finish
You are buying the equipment from us and the labour from an installer you choose. Two numbers instead of one bundled quote — which is the point, but it does mean you are the one connecting them. Here is the whole sequence.
- Order the equipment. The price on this page is what you pay us. Nothing about installation is included in it, and nothing is added later.
- Line up your installer before it ships. This is the step people skip, and it is the one that causes trouble — equipment sitting in a garage while you ring round for someone free. You need a licensed HVAC professional; opening a refrigerant circuit requires EPA certification. Ask specifically what they charge to install customer-supplied equipment. How to find one.
- It ships crated on a freight truck. Orders typically ship within 3–7 business days. A complete system travels as two crates — condenser and air handler — which can arrive on different days. Delivery is to your address on a liftgate truck for one flat price, with nothing to choose at checkout. What delivery costs.
- The carrier calls to book a delivery window. That appointment is when your equipment arrives — not the ship date. Answer the call; an unanswered one is the most common cause of a delay.
- Inspect it before you sign. Two minutes at the tail of the truck decide whether a damage claim works. Note any damage on the delivery receipt specifically, not just "damaged", and photograph it before it comes off the truck. What to check.
- Your installer fits it, then register the warranty. Line set, disconnect, whip, thermostat and equipment pad are not included — your installer supplies those. Registering within 60 days of installation takes about four minutes and extends parts coverage from five years to ten. Warranty terms.
Stuck on any of it, or not sure a pairing is right? Call (239) 266-9766 — you will get someone who installs this equipment.