{"title":"Everwell","description":"\u003cp\u003eEverwell's value line — CAC-15 condensers, AHC and FAHC air handlers, complete matched systems, and the MKTH-17 ductless mini-split. GoldFin corrosion-resistant coils, AHRI and ETL certified.\u003c\/p\u003e\u003cp\u003eThe two air handler series are worth telling apart. \u003cb\u003eAHC\u003c\/b\u003e is standard return; \u003cb\u003eFAHC\u003c\/b\u003e is front return, for tighter closets. They take different electric heat kits, and the front-return series has no 15 kW or 20 kW option — so if you need that much strip heat, choose the standard-return handler.\u003c\/p\u003e","products":[{"product_id":"everwell-ahc-air-handler","title":"Everwell AHC Series Air Handler (Standard Return)","description":"\u003cp\u003eThe indoor half of an Everwell system, in the standard-return configuration that suits most residential installs — and the one that takes the big heat kits.\u003c\/p\u003e\n\n\u003ch3\u003eStandard return, and what that means\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the cabinet from the side or the bottom, which is the conventional arrangement and the one most upflow closets and attic platforms are already built for. If your existing handler pulls its return from below, this is the direct replacement. Where the closet cannot accommodate that, the \u003ca href=\"\/products\/everwell-fahc-air-handler\"\u003efront-return FAHC\u003c\/a\u003e is the alternative.\u003c\/p\u003e\n\n\u003ch3\u003eIt takes strip heat up to 20 kW\u003c\/h3\u003e\n\u003cp\u003eThis is the practical reason to choose the AHC over the front-return version. The \u003ca href=\"\/products\/electric-heat-kit-everwell-ahc-series-standard-return\"\u003eWTM heat kit\u003c\/a\u003e range runs from 5 kW to 20 kW.\u003c\/p\u003e\n\u003cp\u003eThat matters in two situations. On a heat pump, the strips carry the house through a defrost cycle and through the coldest hours when the outdoor unit's capacity falls. On an air-conditioner system with no furnace, \u003cb\u003ethe heat kit is the only heat in the house\u003c\/b\u003e — and the FAHC series does not offer the 15 kW or 20 kW sizes.\u003c\/p\u003e\n\n\u003ch3\u003eWhy there is no SEER2 figure on this page\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eAn air handler has no efficiency rating of its own.\u003c\/b\u003e SEER2 is certified for a matched pair — a specific outdoor unit against a specific indoor one — so the number belongs to the combination, not to either box separately. Pair this with a \u003ca href=\"\/products\/everwell-cac-15-r454b-cooling\"\u003eCAC-15 air conditioner\u003c\/a\u003e or a \u003ca href=\"\/products\/everwell-cac-15-r454b-heat-pump\"\u003eCAC-15 heat pump\u003c\/a\u003e and the certified rating for that pairing is published on the \u003ca href=\"\/collections\/central-air-systems\"\u003ecomplete system listing\u003c\/a\u003e, with the AHRI certificate linked. Or \u003ca href=\"\/pages\/ahri-match-check\"\u003echeck any pairing yourself\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating. The indoor coil runs wet every cooling hour, which makes it the surface that suffers most in permanent humidity — and in coastal Florida it is where standard coatings fail first.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 5 ton\u003c\/h3\u003e\n\u003cp\u003eFour cabinets covering 1.5 through 5 ton. Match the handler to the condenser and to a Manual J load calculation from someone who has seen the property, not to the size of the unit being replaced.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — opening a refrigerant circuit requires EPA certification, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eCrated at 22.83 × 25.6 × 47.63 in on the 1.5–3.5 ton cabinets, 25.2 × 27.75 × 54.9 in on the 5 ton\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and pad are not included\u003c\/li\u003e\n\u003cli\u003eShips on a freight truck — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 – 2 Ton","offer_id":49310250336515,"sku":"AHC2414BA15","price":1249.0,"currency_code":"USD","in_stock":true},{"title":"2.5 – 3 Ton","offer_id":49310250369283,"sku":"AHC3614BA15","price":1269.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310250402051,"sku":"AHC4214BA15","price":1349.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310250434819,"sku":"AHC6014BA15","price":1569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-ahc.png?v=1784771685"},{"product_id":"everwell-fahc-air-handler","title":"Everwell FAHC Series Air Handler (Front Return)","description":"\u003cp\u003eThe same Everwell indoor unit in a front-return cabinet — narrower, shorter, and built for the closet a standard-return handler will not fit.\u003c\/p\u003e\n\n\u003ch3\u003eFront return, and when you need it\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the front of the cabinet rather than the side or bottom. That reads like a detail until you are standing in a hallway closet with no route to bring a return in from below — common in older Florida houses, and in any retrofit where the mechanical space was sized for equipment nobody makes any more.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIt is also physically smaller.\u003c\/b\u003e The 1.5–2 ton crates at 23.2 × 17.7 × 39.4 in against the standard-return AHC's 22.83 × 25.6 × 47.63 — roughly eight inches shorter and eight inches narrower. Measure the space before you choose between them.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it does not do\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eNo 15 kW or 20 kW heat kit on this series.\u003c\/b\u003e The \u003ca href=\"\/products\/electric-heat-kit-everwell-fahc-series-front-return\"\u003eWFM heat kit\u003c\/a\u003e covers the smaller outputs. If this is a straight air-conditioner system with no furnace in the house, the strips are the only heat there is — and if you need the larger sizes, the \u003ca href=\"\/products\/everwell-ahc-air-handler\"\u003estandard-return AHC\u003c\/a\u003e takes them.\u003c\/p\u003e\n\u003cp\u003eThe range also stops at 3 ton. Above that, the AHC carries it to 5.\u003c\/p\u003e\n\n\u003ch3\u003eWhy there is no SEER2 figure on this page\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eAn air handler has no efficiency rating of its own.\u003c\/b\u003e SEER2 is certified for a matched pair — one specific outdoor unit against one specific indoor unit — so the number belongs to the combination rather than to either box. Pair this with a \u003ca href=\"\/products\/everwell-cac-15-r454b-cooling\"\u003eCAC-15 air conditioner\u003c\/a\u003e or a \u003ca href=\"\/products\/everwell-cac-15-r454b-heat-pump\"\u003eCAC-15 heat pump\u003c\/a\u003e and the certified figure for that pairing is on the \u003ca href=\"\/collections\/central-air-systems\"\u003ecomplete system listing\u003c\/a\u003e, with the AHRI certificate linked. Or \u003ca href=\"\/pages\/ahri-match-check\"\u003echeck any pairing yourself\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating. The indoor coil runs wet every cooling hour, so it is the surface that suffers most in permanent humidity — and on the coast it is where standard coatings fail first.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — opening a refrigerant circuit requires EPA certification, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eTwo sizes: 1.5–2 ton and 2.5–3 ton\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and pad are not included\u003c\/li\u003e\n\u003cli\u003eShips on a freight truck — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 – 2 Ton","offer_id":49310250467587,"sku":"FAHC2414BA15","price":1269.42,"currency_code":"USD","in_stock":true},{"title":"2.5 – 3 Ton","offer_id":49310250500355,"sku":"FAHC3614BA15","price":1289.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-fahc.png?v=1784771686"},{"product_id":"everwell-mkth-17-mini-split-heat-pump","title":"Everwell MKTH-17 Single-Zone Wall Mount Ductless Mini Split Heat Pump — 12,000-36,000 BTU, up to 20 SEER2, R-32","description":"\u003cp\u003eThe Everwell MKTH-17 is a single-zone ductless mini-split that heats and cools one space efficiently — perfect for additions, garages, bonus rooms, or anywhere ductwork won't reach. Inverter-driven operation holds a steady 17 SEER2 efficiency without the on\/off cycling of older systems, keeping comfort consistent and bills low. It installs with minimal disruption (no ducts required) and arrives ready for wall-mounted comfort with the install components included. Quiet, efficient, and simple — ductless comfort made easy.\u003c\/p\u003e","brand":"Everwell","offers":[{"title":"12,000 BTU · 115V","offer_id":49310250533123,"sku":"MKTH1215X-17","price":789.0,"currency_code":"USD","in_stock":true},{"title":"12,000 BTU · 208-230V","offer_id":49310250565891,"sku":"MKTH1225X-17","price":789.0,"currency_code":"USD","in_stock":true},{"title":"18,000 BTU · 208-230V","offer_id":49310250598659,"sku":"MKTH1825X-17","price":842.0,"currency_code":"USD","in_stock":true},{"title":"24,000 BTU · 208-230V","offer_id":49310250631427,"sku":"MKTH2425X-17","price":1259.0,"currency_code":"USD","in_stock":true},{"title":"36,000 BTU · 208-230V","offer_id":49310250664195,"sku":"MKTH3625X-17","price":2427.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-mkth17.png?v=1784771687"},{"product_id":"everwell-cac-15-r454b-heat-pump","title":"Everwell CAC-15 R-454B Heat Pump (14.3 SEER2)","description":"\u003ch3\u003eHeats and cools, with a ten-year warranty behind it\u003c\/h3\u003e\n\u003cp\u003eOne outdoor unit for both seasons, and no furnace, gas line or flue anywhere in the system. The warranty is what makes this worth considering against a better-known badge: ten years on compressor and parts, five on the coil, with registration. A heat pump runs far more hours a year than an air conditioner does, so warranty length matters more here than it does on a cooling-only unit. Register it at commissioning — there is a deadline, and our warranty page sets out the terms.\u003c\/p\u003e\n\n\u003ch3\u003eKnow the heating floor before you buy\u003c\/h3\u003e\n\u003cp\u003eRated for heating down to 17°F ambient, and cooling from 61°F to 118°F. In Florida and the Gulf South, 17°F is below anything you will see in a normal winter, and the air handler's electric strip heat covers the rare night that approaches it. Further north it is a real constraint, and you would want a cold-climate heat pump instead. We would rather say that plainly than sell you a unit that underperforms every January.\u003c\/p\u003e\n\n\u003ch3\u003eAn LG scroll compressor\u003c\/h3\u003e\n\u003cp\u003eSingle-stage, from a manufacturer whose compressors appear throughout the industry. On a heat pump the compressor and reversing valve work year round, so this is not a detail to skim — it is the main reason this unit is a different proposition from the cheapest condenser available online.\u003c\/p\u003e\n\n\u003ch3\u003eGoldFin coated copper coil\u003c\/h3\u003e\n\u003cp\u003eAll-copper with a corrosion-resistant coating. Copper transfers heat well and, importantly, \u003cstrong\u003ecan be repaired in place with a torch by any technician\u003c\/strong\u003e, where an aluminium coil leak usually means coil replacement. The coating is what protects it from salt air and sustained humidity. Top-discharge cabinet, around 65 dB.\u003c\/p\u003e\n\n\u003ch3\u003eThe heat kit decision that has to be made now\u003c\/h3\u003e\n\u003cp\u003eSupplemental heat lives in the air handler, not out here, and on Everwell the handler choice constrains it: the \u003cstrong\u003eAHC standard-return handler takes strip heat up to 20 kW, while the FAHC front-return handler stops at 10 kW\u003c\/strong\u003e. If your house needs 15 or 20 kW of backup heat, you must choose the AHC handler — the front-return cabinet cannot be upgraded to it later. Decide the heat kit size before you pick the handler, not after.\u003c\/p\u003e\n\n\u003ch3\u003eMatching it correctly\u003c\/h3\u003e\n\u003cp\u003eCertified with the Everwell AHC and FAHC air handlers at 14.3 SEER2. The rating belongs to the pair, and we publish the AHRI certificate on every size of the complete systems so you can check the number yourself rather than take ours. Line runs to 148 feet with up to 66 feet of rise; 3\/8 inch liquid and 3\/4 inch gas to 3.5 ton, 7\/8 inch at 4 and 5 ton.\u003c\/p\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310250828035,"sku":"CAC1814HA15","price":1519.0,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310250860803,"sku":"CAC2414HA15","price":1529.0,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310250893571,"sku":"CAC3014HA15","price":1659.0,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310250926339,"sku":"CAC3614HA15","price":1759.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310250959107,"sku":"CAC4214HA15","price":1919.0,"currency_code":"USD","in_stock":true},{"title":"4 Ton","offer_id":49310250991875,"sku":"CAC4814HA15","price":2149.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310251024643,"sku":"CAC6014HA15","price":2179.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-central.png?v=1784771689"},{"product_id":"everwell-cac-15-r454b-cooling","title":"Everwell CAC-15 R-454B Air Conditioner (14.3 SEER2)","description":"\u003ch3\u003eThe warranty is the argument\u003c\/h3\u003e\n\u003cp\u003eTen years on the compressor and parts, five on the coil, with registration. On a value-line condenser that is the headline, because the fear with any brand you have not heard of is what happens in year six when the compressor goes and nobody stands behind it. Registration is required and there is a deadline after installation, so do it when the system is commissioned rather than filing the paperwork somewhere and forgetting — our warranty page explains what is covered and what is not.\u003c\/p\u003e\n\n\u003ch3\u003eAn LG scroll compressor, not an anonymous one\u003c\/h3\u003e\n\u003cp\u003eThe compressor is the part that decides whether a condenser lasts, and it is the part budget equipment usually economises on. This one is an LG scroll — a manufacturer whose compressors are in equipment across the industry, single-stage and straightforward. It is the specific reason this unit is not the same proposition as the cheapest condenser you can find online.\u003c\/p\u003e\n\n\u003ch3\u003eGoldFin coated copper, and why a technician cares\u003c\/h3\u003e\n\u003cp\u003eThe coil is all-copper with a GoldFin corrosion-resistant coating. Copper moves heat better than aluminium and, more usefully, \u003cstrong\u003ea copper coil can be repaired in place by any technician with a torch\u003c\/strong\u003e. Aluminium coils generally cannot — a leak often means replacing the coil. The coating is what handles the salt air and humidity that would otherwise attack copper. If you are on the coast, or eight years out thinking about who fixes a small leak, that combination is worth understanding before you compare spec sheets on price alone.\u003c\/p\u003e\n\n\u003ch3\u003eLong line runs are possible here\u003c\/h3\u003e\n\u003cp\u003eUp to 148 feet of refrigerant line with as much as 66 feet of height difference. That is generous, and it opens up installations that would otherwise be difficult: a condenser placed around the side of the house away from a patio, a handler in a second-floor attic, or a unit serving a detached structure. Line sizes are 3\/8 inch liquid with 3\/4 inch gas up to 3.5 ton, stepping to 7\/8 inch at 4 and 5 ton.\u003c\/p\u003e\n\n\u003ch3\u003eOne limit to know about\u003c\/h3\u003e\n\u003cp\u003eRated for cooling between 61°F and 118°F ambient. The top end is more than Florida asks of it. The bottom end means this is not the unit for a room that needs mechanical cooling in cold weather — a server closet or a wine room running year round — without a low-ambient kit. For a house, it is irrelevant. Top-discharge cabinet with a louvered grille guard, around 65 dB.\u003c\/p\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310251057411,"sku":"CAC1814CA15","price":1449.0,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310251090179,"sku":"CAC2414CA15","price":1499.0,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310251122947,"sku":"CAC3014CA15","price":1629.0,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310251155715,"sku":"CAC3614CA15","price":1649.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310251188483,"sku":"CAC4214CA15","price":1829.0,"currency_code":"USD","in_stock":true},{"title":"4 Ton","offer_id":49310251221251,"sku":"CAC4814CA15","price":1899.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310251254019,"sku":"CAC6014CA15","price":2026.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-central_fe5b9e16-e83b-4a63-8792-ce83824bb023.png?v=1784771690"},{"product_id":"everwell-cac15-ahc-air-conditioner-complete-system","title":"Everwell CAC-15 Air Conditioner — Complete System with AHC Air Handler","description":"\u003cp\u003eThe Everwell CAC-15 condenser matched to the AHC standard-return air handler — the least expensive complete matched system we sell, and one that arrives with its AHRI certificate published rather than promised.\u003c\/p\u003e\n\n\u003ch3\u003eWhat ships\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOutdoor unit\u003c\/b\u003e — Everwell CAC-15 R-454B condenser, GoldFin™-coated all-copper coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndoor unit\u003c\/b\u003e — Everwell AHC standard-return air handler\u003c\/li\u003e\n\u003cli\u003eTwo crates, shipped together as an AHRI-certified matched pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat it actually rates\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e14.3 SEER2 from 1.5 through 4 ton. The 5 ton pairing certifies at 13.8.\u003c\/b\u003e That figure belongs to this specific condenser and this specific air handler together — not to the box outside — which is why we publish it per size instead of printing one number across the range.\u003c\/p\u003e\n\u003cp\u003eEverwell publishes a certificate for every matched pair, and the link for the size you select is in the documents on this page. You can read the certified rating yourself before you spend anything. Not sure whether a pair you were quoted elsewhere is certified? \u003ca href=\"\/pages\/ahri-match-check\"\u003eCheck it here\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating, aimed at the thing that actually kills condensers in this state. Salt air and permanent humidity are where standard coil coatings fail early, and on the Gulf Coast that is what decides whether a unit gives you twelve years or twenty.\u003c\/p\u003e\n\n\u003ch3\u003eThe AHC air handler\u003c\/h3\u003e\n\u003cp\u003eStandard return — the duct enters the cabinet the conventional way, which suits most upflow closet and attic installs. \u003cb\u003eIt also takes the larger strip heat.\u003c\/b\u003e The \u003ca href=\"\/products\/electric-heat-kit-everwell-ahc-series-standard-return\"\u003eEverwell AHC heat kit\u003c\/a\u003e goes up to 20 kW, and this is a cooling-only system, so if there is no furnace in the house that kit is the only heat there is. Choose this handler over the front-return FAHC if you need those sizes.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 5 ton\u003c\/h3\u003e\n\u003cp\u003eSeven capacities. Get a Manual J load calculation from a contractor who has walked the property. An oversized system short-cycles, never pulls the humidity out, and costs more to run than a correctly sized smaller one — sizing beats efficiency every time.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — opening a refrigerant circuit requires EPA certification, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and equipment pad are not included\u003c\/li\u003e\n\u003cli\u003eCooling only. For heat from the same outdoor unit, see the \u003ca href=\"\/products\/everwell-cac15-ahc-heat-pump-complete-system\"\u003eCAC-15 heat pump version\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eShips as two crates — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310254465283,"sku":"CAC1814CA15+AHC2414BA15","price":2698.0,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310254498051,"sku":"CAC2414CA15+AHC2414BA15","price":2748.0,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310254530819,"sku":"CAC3014CA15+AHC3614BA15","price":2898.0,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310254563587,"sku":"CAC3614CA15+AHC3614BA15","price":2918.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310254596355,"sku":"CAC4214CA15+AHC4214BA15","price":3178.0,"currency_code":"USD","in_stock":true},{"title":"4 Ton","offer_id":49310254629123,"sku":"CAC4814CA15+AHC6014BA15","price":3468.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310254661891,"sku":"CAC6014CA15+AHC6014BA15","price":3595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-ahc-system.png?v=1784771708"},{"product_id":"everwell-cac15-ahc-heat-pump-complete-system","title":"Everwell CAC-15 Heat Pump — Complete System with AHC Air Handler","description":"\u003cp\u003eThe Everwell CAC-15 heat pump matched to the AHC standard-return air handler. One outdoor unit that both heats and cools, at the lowest price per BTU in this catalogue — no furnace, no gas line, no second piece of equipment.\u003c\/p\u003e\n\n\u003ch3\u003eWhat ships\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOutdoor unit\u003c\/b\u003e — Everwell CAC-15 R-454B heat pump condenser, GoldFin™-coated all-copper coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndoor unit\u003c\/b\u003e — Everwell AHC standard-return air handler\u003c\/li\u003e\n\u003cli\u003eTwo crates, shipped together as an AHRI-certified matched pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat it actually rates\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e14.3 SEER2 cooling and 7.5 HSPF2 heating\u003c\/b\u003e, certified across all seven sizes. Both figures belong to this exact pairing rather than to the condenser on its own — Everwell publishes a certificate for each one, and the link for the size you select is in the documents on this page.\u003c\/p\u003e\n\u003cp\u003eHolding a quote from somebody else? \u003ca href=\"\/pages\/ahri-match-check\"\u003ePut the two model numbers in here\u003c\/a\u003e and we will tell you whether that combination carries a certified rating.\u003c\/p\u003e\n\n\u003ch3\u003eHow a heat pump heats\u003c\/h3\u003e\n\u003cp\u003eRather than burning fuel, it runs the cooling cycle backwards and moves heat from outside air into the house — which is why it costs less to run than strip heat, and why it works so well in Florida. Two things are worth knowing before you buy one: capacity falls as the outdoor temperature drops, and the unit stops producing heat entirely during a defrost cycle.\u003c\/p\u003e\n\u003cp\u003eThat is what the \u003ca href=\"\/products\/electric-heat-kit-everwell-ahc-series-standard-return\"\u003eAHC electric heat kit\u003c\/a\u003e is for. It carries the house through both. In this climate that is a handful of hours a year; further north it is a great deal more.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating, built for salt air and permanent humidity — the conditions that make standard coil coatings fail early on the Gulf Coast. A heat pump runs year-round rather than eight months, so it spends more hours exposed to exactly that.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 5 ton\u003c\/h3\u003e\n\u003cp\u003eSeven capacities. Get a Manual J load calculation from a contractor who has seen the property. Oversizing a heat pump is worse than oversizing an air conditioner: it short-cycles in both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — EPA certification is required to open a refrigerant circuit, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and equipment pad are not included\u003c\/li\u003e\n\u003cli\u003eCooling only is cheaper if the house already has heat — see the \u003ca href=\"\/products\/everwell-cac15-ahc-air-conditioner-complete-system\"\u003eCAC-15 air conditioner version\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eShips as two crates — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310254694659,"sku":"CAC1814HA15+AHC2414BA15","price":2768.0,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310254727427,"sku":"CAC2414HA15+AHC2414BA15","price":2778.0,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310254760195,"sku":"CAC3014HA15+AHC3614BA15","price":2928.0,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310254792963,"sku":"CAC3614HA15+AHC3614BA15","price":3028.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310254825731,"sku":"CAC4214HA15+AHC4214BA15","price":3268.0,"currency_code":"USD","in_stock":true},{"title":"4 Ton","offer_id":49310254858499,"sku":"CAC4814HA15+AHC6014BA15","price":3718.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310254891267,"sku":"CAC6014HA15+AHC6014BA15","price":3748.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-ahc-system_73aacee8-eceb-4ae3-9a86-2482345f4aac.png?v=1784771709"},{"product_id":"everwell-cac15-fahc-air-conditioner-complete-system","title":"Everwell CAC-15 Air Conditioner — Complete System with FAHC Front-Return Air Handler","description":"\u003cp\u003eThe Everwell CAC-15 condenser matched to the FAHC front-return air handler — the version for a closet that will not take a standard return. Same condenser, same certified pairing, a cabinet that fits where the other one does not.\u003c\/p\u003e\n\n\u003ch3\u003eWhat ships\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOutdoor unit\u003c\/b\u003e — Everwell CAC-15 R-454B condenser, GoldFin™-coated all-copper coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndoor unit\u003c\/b\u003e — Everwell FAHC front-return air handler\u003c\/li\u003e\n\u003cli\u003eTwo crates, shipped together as an AHRI-certified matched pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFront return, and when it matters\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the front of the cabinet rather than the side or bottom. That sounds like a detail until you are standing in a hallway closet with no room to bring a return in from below — which is a common problem in older Florida houses and in any retrofit where the mechanical space was sized for equipment that is no longer made.\u003c\/p\u003e\n\u003cp\u003eThe FAHC is also physically smaller: the crate is 23.2 × 17.7 × 39.4 inches against the AHC's 22.83 × 25.6 × 47.63. If the existing closet is tight, measure before you choose.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it actually rates\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e14.3 SEER2\u003c\/b\u003e, certified across all four sizes. That figure belongs to this condenser and this air handler together, not to the outdoor unit alone. Everwell publishes the certificate for each pairing and the link for the size you select is in the documents on this page — or \u003ca href=\"\/pages\/ahri-match-check\"\u003echeck any pairing yourself\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating, built for the salt air and permanent humidity that make standard coatings fail early on the Gulf Coast.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 3 ton\u003c\/h3\u003e\n\u003cp\u003eFour capacities. The FAHC series tops out at 3 ton; above that, the \u003ca href=\"\/products\/everwell-cac15-ahc-air-conditioner-complete-system\"\u003estandard-return AHC version\u003c\/a\u003e runs to 5. Get a Manual J from someone who has walked the property — an oversized system never dehumidifies, whichever cabinet it lives in.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — EPA certification is required to open a refrigerant circuit, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNo 15 kW or 20 kW heat kit on this series.\u003c\/b\u003e The \u003ca href=\"\/products\/electric-heat-kit-everwell-fahc-series-front-return\"\u003eFAHC strip heat\u003c\/a\u003e covers the smaller sizes; if this is the only heat in the house and you need the larger output, choose the AHC version instead\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and equipment pad are not included\u003c\/li\u003e\n\u003cli\u003eShips as two crates — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310254924035,"sku":"CAC1814CA15+FAHC2414BA15","price":2718.42,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310254956803,"sku":"CAC2414CA15+FAHC2414BA15","price":2768.42,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310254989571,"sku":"CAC3014CA15+FAHC3614BA15","price":2918.42,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310255022339,"sku":"CAC3614CA15+FAHC3614BA15","price":2938.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-fahc-system.png?v=1784771710"},{"product_id":"everwell-cac15-fahc-heat-pump-complete-system","title":"Everwell CAC-15 Heat Pump — Complete System with FAHC Front-Return Air Handler","description":"\u003cp\u003eThe Everwell CAC-15 heat pump matched to the FAHC front-return air handler. Heating and cooling from one outdoor unit, in the cabinet that fits a closet a standard-return handler will not.\u003c\/p\u003e\n\n\u003ch3\u003eWhat ships\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eOutdoor unit\u003c\/b\u003e — Everwell CAC-15 R-454B heat pump condenser, GoldFin™-coated all-copper coil\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndoor unit\u003c\/b\u003e — Everwell FAHC front-return air handler\u003c\/li\u003e\n\u003cli\u003eTwo crates, shipped together as an AHRI-certified matched pair\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFront return, and when it matters\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the front of the cabinet instead of the side or bottom, and the crate is smaller — 23.2 × 17.7 × 39.4 inches against the AHC's 22.83 × 25.6 × 47.63. That is the whole reason this version exists: hallway closets in older Florida houses often have no route to bring a return in from below. Measure the space before you choose between the two.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it actually rates\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e14.3 SEER2 cooling and 7.5 HSPF2 heating\u003c\/b\u003e, certified across all four sizes — for this pairing specifically, not for the condenser on its own. Everwell publishes a certificate per pair and the link for your size is in the documents on this page. Quoted a different combination elsewhere? \u003ca href=\"\/pages\/ahri-match-check\"\u003eCheck whether it is certified\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eHow a heat pump heats\u003c\/h3\u003e\n\u003cp\u003eIt runs the cooling cycle backwards, moving heat from outside air into the house rather than burning fuel to make it — cheaper to run than strip heat, and well suited to this climate. Capacity does fall as the outdoor temperature drops, and the unit stops producing heat during a defrost cycle, which is what the \u003ca href=\"\/products\/electric-heat-kit-everwell-fahc-series-front-return\"\u003eFAHC electric heat kit\u003c\/a\u003e covers.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 3 ton\u003c\/h3\u003e\n\u003cp\u003eFour capacities. The FAHC series stops at 3 ton; for 3.5 through 5, the \u003ca href=\"\/products\/everwell-cac15-ahc-heat-pump-complete-system\"\u003estandard-return AHC version\u003c\/a\u003e carries the range. Manual J first — oversizing a heat pump short-cycles it in both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — EPA certification is required to open a refrigerant circuit, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNo 15 kW or 20 kW heat kit on this series\u003c\/b\u003e — choose the AHC version if you need that output for backup heat\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and equipment pad are not included\u003c\/li\u003e\n\u003cli\u003eShips as two crates — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 Ton","offer_id":49310255055107,"sku":"CAC1814HA15+FAHC2414BA15","price":2788.42,"currency_code":"USD","in_stock":true},{"title":"2 Ton","offer_id":49310255087875,"sku":"CAC2414HA15+FAHC2414BA15","price":2798.42,"currency_code":"USD","in_stock":true},{"title":"2.5 Ton","offer_id":49310255120643,"sku":"CAC3014HA15+FAHC3614BA15","price":2948.42,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310255153411,"sku":"CAC3614HA15+FAHC3614BA15","price":3048.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-fahc-system_af98cc70-60a9-4aae-ad1b-9f6fc82be83c.png?v=1784771711"},{"product_id":"electric-heat-kit-everwell-ahc-series-standard-return","title":"Everwell Electric Heat Kit — Standard-Return Air Handlers","description":"\u003cp\u003eField-installed electric strip heater with integrated circuit breaker for Everwell \u003cstrong\u003eAHC standard-return\u003c\/strong\u003e air handlers. 208–230V, single phase, 60 Hz.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e these kits fit AHC series air handlers only. Front-return FAHC air handlers use the WFM series instead. Confirm your air handler model and breaker sizing before ordering.\u003c\/p\u003e","brand":"Everwell","offers":[{"title":"5 kW","offer_id":49373444047107,"sku":"WTM0502BE","price":129.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":49373444079875,"sku":"WTM0802BE","price":159.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":49373444112643,"sku":"WTM1002BE","price":189.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":49373444145411,"sku":"WTM1502BE","price":275.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":49373444178179,"sku":"ECHK-20A","price":330.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/heat-kit-2048_ce13bdd3-265a-4aa4-8bfc-694d8ca18304.jpg?v=1788639532"},{"product_id":"electric-heat-kit-everwell-fahc-series-front-return","title":"Everwell Electric Heat Kit — Front-Return Air Handlers","description":"\u003cp\u003eField-installed electric strip heater with integrated circuit breaker for Everwell \u003cstrong\u003eFAHC front-return\u003c\/strong\u003e air handlers. 208–230V, single phase, 60 Hz.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e these kits fit FAHC front-return air handlers only. Standard-return AHC air handlers use the WTM series instead. Confirm your air handler model and breaker sizing before ordering.\u003c\/p\u003e","brand":"Everwell","offers":[{"title":"5 kW","offer_id":49373444210947,"sku":"WFM0502BE","price":133.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":49373444243715,"sku":"WFM0802BE","price":157.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":49373444276483,"sku":"WFM1002BE","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/heat-kit-2048_53d8b269-987f-4a19-80f9-4b1f0a911cfb.jpg?v=1788639532"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/collections\/hf_20260909_210314_af3af7a1-cebf-4003-99e0-9c211ddf8ac6.png?v=1788988423","url":"https:\/\/hvacsupplypro.com\/collections\/everwell.oembed","provider":"HVAC Supply Pro","version":"1.0","type":"link"}