{"title":"Air Handlers","description":"\u003cp\u003eThe indoor half of a split system — blower, evaporator coil and cabinet. Which one you choose sets the efficiency of the finished system, the airflow, and whether it physically fits the space you have.\u003c\/p\u003e\u003cp\u003eTrane's \u003cb\u003e5TEM4\u003c\/b\u003e is multi-position, the \u003cb\u003eHyperion 5TAM5\u003c\/b\u003e is multi-speed, and the \u003cb\u003e5TMM5 Compact Plus\u003c\/b\u003e mounts on a wall where there is no closet. RunTru's \u003cb\u003eA5AHC\u003c\/b\u003e is multi-position. Everwell's \u003cb\u003eAHC\u003c\/b\u003e is standard return and \u003cb\u003eFAHC\u003c\/b\u003e is front return. Electric heat kits are specific to the series — check the kit fits the handler before you order.\u003c\/p\u003e","products":[{"product_id":"runtru-air-handler-a5ahc","title":"RunTru A5AHC Air Handler — 1.5 to 5 Ton, Multi-Position, R-454B","description":"\u003ch3\u003eHalf the system, and half the rating\u003c\/h3\u003e\n\u003cp\u003eAn air handler is not an accessory to the unit outside. It holds the indoor coil, the blower and the filter, and the efficiency printed on your AHRI certificate belongs to the \u003cem\u003epair\u003c\/em\u003e rather than to the condenser. Put a mismatched coil behind a good condenser and the system will never reach the number it was sold on. The A5AHC exists so the RunTru A5AC and A5HP condensers have an indoor half they are actually certified with.\u003c\/p\u003e\n\n\u003ch3\u003eMulti-position, which is what solves the closet problem\u003c\/h3\u003e\n\u003cp\u003eUpflow, downflow or horizontal from a single cabinet. This matters more than it sounds, because the building dictates the orientation and the catalog does not: a Florida garage or attic usually wants horizontal, a hallway closet wants upflow, a unit sitting over a crawlspace may want downflow. One model covers all three, so nobody discovers on installation day that the wrong configuration was ordered.\u003c\/p\u003e\n\n\u003ch3\u003eThe blower is what you actually feel\u003c\/h3\u003e\n\u003cp\u003eCapacity gets the attention, but airflow is what the room experiences. A blower that can run longer at a lower speed pulls more moisture out of the air than one that blasts and shuts off, and in the Southeast humidity is at least half of what \"comfortable\" means. It is also the difference between a system you can hear from the next room and one you cannot.\u003c\/p\u003e\n\n\u003ch3\u003eAll-aluminum coil\u003c\/h3\u003e\n\u003cp\u003eThe coil is all-aluminum rather than copper tube with aluminum fins. Mixing the two metals in a humid or salt-air environment invites galvanic corrosion, which is the most common reason an indoor coil leaks refrigerant years before the rest of the system is worn out. A single-metal coil removes that failure mode entirely.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to order alongside it\u003c\/h3\u003e\n\u003cp\u003eIf you are pairing this with a heat pump, supplemental heat lives \u003cem\u003ehere\u003c\/em\u003e, not in the outdoor unit — it is an electric heat kit that slots into the air handler and is sized in kilowatts for your climate and house. It is sold separately and listed in our accessories; your installer should specify the kW rating. This is the single most commonly forgotten item on a heat pump order.\u003c\/p\u003e\n\n\u003ch3\u003eMatching it correctly\u003c\/h3\u003e\n\u003cp\u003eDesigned to match the RunTru A5AC and A5HP outdoor units. Check the AHRI reference number published on the listing for the exact combination you intend to install — and if you would rather not assemble the match yourself, the complete systems are listed as single items.\u003c\/p\u003e","brand":"RunTru by Trane","offers":[{"title":"1.5 – 2 Ton","offer_id":49310249582851,"sku":"A5AHC002A1B30A","price":1550.0,"currency_code":"USD","in_stock":true},{"title":"1.5 – 2.5 Ton","offer_id":49310249615619,"sku":"A5AHC003A1B30A","price":1625.0,"currency_code":"USD","in_stock":true},{"title":"2 – 3 Ton","offer_id":49310249648387,"sku":"A5AHC004A1B30A","price":1685.0,"currency_code":"USD","in_stock":true},{"title":"3 – 4 Ton (A5AHC005)","offer_id":49310249681155,"sku":"A5AHC005A1D30A","price":1845.0,"currency_code":"USD","in_stock":true},{"title":"3 – 4 Ton (A5AHC006)","offer_id":49310249713923,"sku":"A5AHC006A1D30A","price":1910.0,"currency_code":"USD","in_stock":true},{"title":"3.5 – 5 Ton","offer_id":49310249746691,"sku":"A5AHC007A1D30A","price":2145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/hf_20260829_204047_fdab8ffc-44a6-4423-8961-798fd69719b2.png?v=1788036189"},{"product_id":"trane-air-handler-5tem4","title":"Trane 5TEM4 Air Handler — 1.5 to 5 Ton, Convertible Multi-Position, R-454B","description":"\u003ch3\u003eTrane's workhorse indoor half\u003c\/h3\u003e\n\u003cp\u003eThe 5TEM4 is the air handler most Trane split systems in this catalog are built around. It is the convertible, multi-position cabinet that pairs with the 5TTR and 5TWR condensers, and it is the match behind most of the certified ratings you will see on our complete systems. If you are buying a Trane condenser and have no specific reason to choose otherwise, this is the handler that goes with it.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the ECM blower changes\u003c\/h3\u003e\n\u003cp\u003eAn ECM blower is an electronically commutated motor, and the practical difference is that it can run at part speed instead of only full speed. Two consequences you will notice: it draws substantially fewer watts across a season than an old PSC motor, because fan power falls faster than fan speed does; and it can hold a long, low airflow that strips humidity out of the house instead of short-cycling. In a climate where the discomfort is moisture rather than heat, that second point is the one that matters.\u003c\/p\u003e\n\n\u003ch3\u003eConvertible, so the building decides\u003c\/h3\u003e\n\u003cp\u003eUpflow, downflow and horizontal from one cabinet, configured at installation. An attic install goes horizontal, a closet goes upflow, and neither requires a different part number. The cabinet is insulated and factory-sealed, which keeps conditioned air inside the box rather than losing it into an unconditioned attic before it reaches a register.\u003c\/p\u003e\n\n\u003ch3\u003eIt sets your efficiency, not the condenser\u003c\/h3\u003e\n\u003cp\u003eSEER2 is a property of the certified pair. The same 5TTR6 condenser certifies at different numbers depending on which indoor unit is behind it — around 15.2 SEER2 with this handler, and higher with the Hyperion 5TAM5. Neither is wrong; they are different systems. Read the AHRI reference number for the exact combination rather than the headline figure on any one component.\u003c\/p\u003e\n\n\u003ch3\u003eHeat kit sold separately\u003c\/h3\u003e\n\u003cp\u003eOn a heat pump, or for auxiliary heat on a cooling-only system, the electric heat kit installs in this cabinet and is sized in kilowatts. It is listed in our accessories and is the item most often left off an order. Your installer should specify the rating for your house and climate.\u003c\/p\u003e","brand":"Trane","offers":[{"title":"1.5 – 2 Ton","offer_id":49310249779459,"sku":"5TEM4B02","price":1920.0,"currency_code":"USD","in_stock":true},{"title":"1.5 – 2.5 Ton","offer_id":49310249812227,"sku":"5TEM4B03","price":2040.0,"currency_code":"USD","in_stock":true},{"title":"2 – 3 Ton","offer_id":49310249844995,"sku":"5TEM4B04","price":2160.0,"currency_code":"USD","in_stock":true},{"title":"3 – 4 Ton (5TEM4D05)","offer_id":49310249877763,"sku":"5TEM4D05","price":2275.0,"currency_code":"USD","in_stock":true},{"title":"3 – 4 Ton (5TEM4D06)","offer_id":49310249910531,"sku":"5TEM4D06","price":2395.0,"currency_code":"USD","in_stock":true},{"title":"3.5 – 5 Ton","offer_id":49310249943299,"sku":"5TEM4D07","price":2790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/hf_20260829_200153_fb5bf4ec-7241-4d16-aacb-e0e0c1964709.png?v=1788034396"},{"product_id":"trane-5tam5-air-handler","title":"Trane Hyperion 5TAM5 Multi-Speed Air Handler — 1.5 to 5 Ton, R-454B","description":"\u003ch3\u003eThe quiet one, and the reason is the cabinet\u003c\/h3\u003e\n\u003cp\u003eThe Hyperion 5TAM5 is built around a double-walled cabinet: the insulation is sandwiched between two sheets of metal instead of being glued to the inside of one. Two things follow. The insulation never sits in the airstream, so it cannot shed fibres into the air you breathe or degrade over fifteen years of airflow across its face. And a double wall is far stiffer than a single one, so less blower noise radiates out of the box — which is why this is the handler to specify when the air handler lives in a closet off a bedroom or hallway rather than out in a garage.\u003c\/p\u003e\n\n\u003ch3\u003eIt raises the efficiency of the condenser you already chose\u003c\/h3\u003e\n\u003cp\u003eThis is the part buyers underestimate. SEER2 belongs to the certified pair, and the indoor half moves the number substantially. The same 5TTR6 condenser certifies around 15.2 SEER2 behind the 5TEM4 handler and as high as 17 SEER2 behind this one. That is the same outdoor unit, the same refrigerant, the same installation — a different indoor coil and blower. If you are weighing a more efficient condenser against a better air handler, price both paths before deciding, because upgrading the handler is often the cheaper route to the same certificate.\u003c\/p\u003e\n\n\u003ch3\u003eThe Vortica blower\u003c\/h3\u003e\n\u003cp\u003eA multi-speed blower that can hold a long, low airflow rather than cycling hard. Longer run times at lower speed remove more humidity per hour of operation, and in the Southeast the difference between 55% and 45% indoor relative humidity is felt more than a degree or two of temperature. It is also gentler on ductwork that was never sized generously in the first place.\u003c\/p\u003e\n\n\u003ch3\u003eWhere it fits\u003c\/h3\u003e\n\u003cp\u003e1.5 to 5 ton, pairing with Trane 5TTR and 5TWR condensers, on R-454B. Which condenser you put it with sets the certified efficiency, so read the AHRI reference number for your exact combination rather than assuming the handler alone determines it.\u003c\/p\u003e\n\n\u003ch3\u003eHeat kit\u003c\/h3\u003e\n\u003cp\u003eTakes the Trane BAYHTR electric heat kit for supplemental or backup heat, sized in kilowatts and sold separately. Required on a heat pump, optional on a cooling-only system, and routinely left off orders — have your installer specify the rating.\u003c\/p\u003e","brand":"Trane","offers":[{"title":"1.5 – 2 Ton (5TAM5B01AC21S)","offer_id":49310249976067,"sku":"5TAM5B01AC21S","price":2715.0,"currency_code":"USD","in_stock":true},{"title":"1.5 – 2 Ton (5TAM5B02AC21S)","offer_id":49310250008835,"sku":"5TAM5B02AC21S","price":2815.0,"currency_code":"USD","in_stock":true},{"title":"2 – 3 Ton (5TAM5C03AC21S)","offer_id":49310250041603,"sku":"5TAM5C03AC21S","price":2920.0,"currency_code":"USD","in_stock":true},{"title":"2 – 3 Ton (5TAM5C04AC31S)","offer_id":49310250074371,"sku":"5TAM5C04AC31S","price":3020.0,"currency_code":"USD","in_stock":true},{"title":"3 – 4 Ton","offer_id":49310250107139,"sku":"5TAM5D05AC31S","price":3205.0,"currency_code":"USD","in_stock":true},{"title":"3.5 – 5 Ton","offer_id":49310250139907,"sku":"5TAM5D06AC41S","price":3390.0,"currency_code":"USD","in_stock":true},{"title":"4 – 5 Ton","offer_id":49310250172675,"sku":"5TAM5D07AC51S","price":3740.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/hf_20260829_204632_40181147-b94d-4468-ab27-7aba9b506e34.png?v=1788036508"},{"product_id":"trane-5tmm5-air-handler","title":"Trane 5TMM5 Compact Plus Wall Mount Air Handler — 1.5 to 3 Ton, R-454B","description":"\u003ch3\u003eFor the room that has no floor to give up\u003c\/h3\u003e\n\u003cp\u003eThe 5TMM5 Compact Plus hangs on a wall. That is the entire reason it exists, and for the right installation nothing else will do. A converted garage, a bonus room over the garage, a sunroom, a mother-in-law addition, an office built into a corner of a workshop — spaces where a conventional upflow cabinet would consume floor area you added the room to gain. It mounts on the wall, leaves the floor clear, and takes standard ducted supply and return rather than the wall-blown air of a mini-split head.\u003c\/p\u003e\n\n\u003ch3\u003e1.5 to 3 ton, and that is a hard ceiling\u003c\/h3\u003e\n\u003cp\u003eThis handler tops out at 3 tons. If your load calculation comes back above that, the 5TEM4 or the Hyperion 5TAM5 is the answer instead — do not try to stretch this one. An undersized handler behind an oversized condenser does not simply perform a little worse; it restricts airflow, drops coil temperature and starts freezing, and the compressor pays for it. Size the load first, then pick the cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eCheck your line routing before ordering\u003c\/h3\u003e\n\u003cp\u003eB0B models bring the refrigerant connections out at the \u003cem\u003etop back\u003c\/em\u003e of the cabinet. On a wall-mounted unit that is not a detail you can improvise around after delivery — the wall, the studs and the existing line set all have opinions. Have whoever is installing it confirm the connection location against the space before you order, because a wall handler with its connections on the wrong face is a return rather than an adjustment.\u003c\/p\u003e\n\n\u003ch3\u003eIt takes a different heat strip\u003c\/h3\u003e\n\u003cp\u003eThis unit uses the BAYHTRA5-BRK heat strip, \u003cstrong\u003enot\u003c\/strong\u003e the standard BAYHTR kit that fits the 5TEM4 and the Hyperion. The two are not interchangeable. If you are ordering supplemental heat with a wall-mount handler, order the bracket-specific strip, and check it against the spec sheet on this page rather than against a heat kit listing written for a floor-standing cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eMatching it correctly\u003c\/h3\u003e\n\u003cp\u003ePairs with Trane 5TTR and 5TWR condensers on R-454B. As with every split system, the certified efficiency belongs to the pair rather than to either half, so read the AHRI reference number for the exact combination you intend to install — it is published on the complete-system listings.\u003c\/p\u003e","brand":"Trane","offers":[{"title":"1.5 – 2.5 Ton (5TMM5B0A30M21S)","offer_id":49310250205443,"sku":"5TMM5B0A30M21S","price":1490.0,"currency_code":"USD","in_stock":true},{"title":"1.5 – 2.5 Ton (5TMM5B0B30M21S)","offer_id":49310250238211,"sku":"5TMM5B0B30M21S","price":1655.0,"currency_code":"USD","in_stock":true},{"title":"2.5 – 3 Ton","offer_id":49310250270979,"sku":"5TMM5B0B36M31S","price":1820.0,"currency_code":"USD","in_stock":true},{"title":"3 Ton","offer_id":49310250303747,"sku":"5TMM5B0C36M31S","price":1985.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/hf_20260830_024625_54f4e0de-0982-4a3d-a7c6-a94541e92f98.png?v=1788058107"},{"product_id":"everwell-ahc-air-handler","title":"Everwell AHC Series Air Handler (Standard Return)","description":"\u003cp\u003eThe indoor half of an Everwell system, in the standard-return configuration that suits most residential installs — and the one that takes the big heat kits.\u003c\/p\u003e\n\n\u003ch3\u003eStandard return, and what that means\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the cabinet from the side or the bottom, which is the conventional arrangement and the one most upflow closets and attic platforms are already built for. If your existing handler pulls its return from below, this is the direct replacement. Where the closet cannot accommodate that, the \u003ca href=\"\/products\/everwell-fahc-air-handler\"\u003efront-return FAHC\u003c\/a\u003e is the alternative.\u003c\/p\u003e\n\n\u003ch3\u003eIt takes strip heat up to 20 kW\u003c\/h3\u003e\n\u003cp\u003eThis is the practical reason to choose the AHC over the front-return version. The \u003ca href=\"\/products\/electric-heat-kit-everwell-ahc-series-standard-return\"\u003eWTM heat kit\u003c\/a\u003e range runs from 5 kW to 20 kW.\u003c\/p\u003e\n\u003cp\u003eThat matters in two situations. On a heat pump, the strips carry the house through a defrost cycle and through the coldest hours when the outdoor unit's capacity falls. On an air-conditioner system with no furnace, \u003cb\u003ethe heat kit is the only heat in the house\u003c\/b\u003e — and the FAHC series does not offer the 15 kW or 20 kW sizes.\u003c\/p\u003e\n\n\u003ch3\u003eWhy there is no SEER2 figure on this page\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eAn air handler has no efficiency rating of its own.\u003c\/b\u003e SEER2 is certified for a matched pair — a specific outdoor unit against a specific indoor one — so the number belongs to the combination, not to either box separately. Pair this with a \u003ca href=\"\/products\/everwell-cac-15-r454b-cooling\"\u003eCAC-15 air conditioner\u003c\/a\u003e or a \u003ca href=\"\/products\/everwell-cac-15-r454b-heat-pump\"\u003eCAC-15 heat pump\u003c\/a\u003e and the certified rating for that pairing is published on the \u003ca href=\"\/collections\/central-air-systems\"\u003ecomplete system listing\u003c\/a\u003e, with the AHRI certificate linked. Or \u003ca href=\"\/pages\/ahri-match-check\"\u003echeck any pairing yourself\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating. The indoor coil runs wet every cooling hour, which makes it the surface that suffers most in permanent humidity — and in coastal Florida it is where standard coatings fail first.\u003c\/p\u003e\n\n\u003ch3\u003eSizing — 1.5 to 5 ton\u003c\/h3\u003e\n\u003cp\u003eFour cabinets covering 1.5 through 5 ton. Match the handler to the condenser and to a Manual J load calculation from someone who has seen the property, not to the size of the unit being replaced.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — opening a refrigerant circuit requires EPA certification, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eCrated at 22.83 × 25.6 × 47.63 in on the 1.5–3.5 ton cabinets, 25.2 × 27.75 × 54.9 in on the 5 ton\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and pad are not included\u003c\/li\u003e\n\u003cli\u003eShips on a freight truck — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 – 2 Ton","offer_id":49310250336515,"sku":"AHC2414BA15","price":1249.0,"currency_code":"USD","in_stock":true},{"title":"2.5 – 3 Ton","offer_id":49310250369283,"sku":"AHC3614BA15","price":1269.0,"currency_code":"USD","in_stock":true},{"title":"3.5 Ton","offer_id":49310250402051,"sku":"AHC4214BA15","price":1349.0,"currency_code":"USD","in_stock":true},{"title":"5 Ton","offer_id":49310250434819,"sku":"AHC6014BA15","price":1569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-ahc.png?v=1784771685"},{"product_id":"everwell-fahc-air-handler","title":"Everwell FAHC Series Air Handler (Front Return)","description":"\u003cp\u003eThe same Everwell indoor unit in a front-return cabinet — narrower, shorter, and built for the closet a standard-return handler will not fit.\u003c\/p\u003e\n\n\u003ch3\u003eFront return, and when you need it\u003c\/h3\u003e\n\u003cp\u003eThe return duct enters the front of the cabinet rather than the side or bottom. That reads like a detail until you are standing in a hallway closet with no route to bring a return in from below — common in older Florida houses, and in any retrofit where the mechanical space was sized for equipment nobody makes any more.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIt is also physically smaller.\u003c\/b\u003e The 1.5–2 ton crates at 23.2 × 17.7 × 39.4 in against the standard-return AHC's 22.83 × 25.6 × 47.63 — roughly eight inches shorter and eight inches narrower. Measure the space before you choose between them.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it does not do\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eNo 15 kW or 20 kW heat kit on this series.\u003c\/b\u003e The \u003ca href=\"\/products\/electric-heat-kit-everwell-fahc-series-front-return\"\u003eWFM heat kit\u003c\/a\u003e covers the smaller outputs. If this is a straight air-conditioner system with no furnace in the house, the strips are the only heat there is — and if you need the larger sizes, the \u003ca href=\"\/products\/everwell-ahc-air-handler\"\u003estandard-return AHC\u003c\/a\u003e takes them.\u003c\/p\u003e\n\u003cp\u003eThe range also stops at 3 ton. Above that, the AHC carries it to 5.\u003c\/p\u003e\n\n\u003ch3\u003eWhy there is no SEER2 figure on this page\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eAn air handler has no efficiency rating of its own.\u003c\/b\u003e SEER2 is certified for a matched pair — one specific outdoor unit against one specific indoor unit — so the number belongs to the combination rather than to either box. Pair this with a \u003ca href=\"\/products\/everwell-cac-15-r454b-cooling\"\u003eCAC-15 air conditioner\u003c\/a\u003e or a \u003ca href=\"\/products\/everwell-cac-15-r454b-heat-pump\"\u003eCAC-15 heat pump\u003c\/a\u003e and the certified figure for that pairing is on the \u003ca href=\"\/collections\/central-air-systems\"\u003ecomplete system listing\u003c\/a\u003e, with the AHRI certificate linked. Or \u003ca href=\"\/pages\/ahri-match-check\"\u003echeck any pairing yourself\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe GoldFin coil\u003c\/h3\u003e\n\u003cp\u003eAn all-copper coil with a corrosion-resistant coating. The indoor coil runs wet every cooling hour, so it is the surface that suffers most in permanent humidity — and on the coast it is where standard coatings fail first.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMust be installed by a licensed HVAC professional — opening a refrigerant circuit requires EPA certification, and the manufacturer warranty depends on it\u003c\/li\u003e\n\u003cli\u003eTwo sizes: 1.5–2 ton and 2.5–3 ton\u003c\/li\u003e\n\u003cli\u003eLine set, disconnect, whip, thermostat and pad are not included\u003c\/li\u003e\n\u003cli\u003eShips on a freight truck — read \u003ca href=\"\/pages\/receiving-a-freight-delivery\"\u003ereceiving a freight delivery\u003c\/a\u003e before delivery day\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Everwell","offers":[{"title":"1.5 – 2 Ton","offer_id":49310250467587,"sku":"FAHC2414BA15","price":1269.42,"currency_code":"USD","in_stock":true},{"title":"2.5 – 3 Ton","offer_id":49310250500355,"sku":"FAHC3614BA15","price":1289.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/files\/everwell-fahc.png?v=1784771686"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3278\/5667\/collections\/hf_20260903_024736_8f0f20c6-6ba2-4535-9daf-0e72514f4475.png?v=1788403979","url":"https:\/\/hvacsupplypro.com\/collections\/air-handlers.oembed","provider":"HVAC Supply Pro","version":"1.0","type":"link"}